What was found
PDIS 745 34-45 3202 26FEB21 MEM OPEN U LOGPAGES:366120 AT APPROXIMATELY 40 KNOTS ON TAKEOFF ROLL @ KMEM, F/O LOST ADI PRESENTATION, #2 YAW DAMPER DISENGAGED, AND WE REC D ECAM IRS #2 FAULT MESSAGE. ABORTED TAKEOFF AND PERFORMED QRH PROCEDURES. R/I 26FEB21 05:53 MEM U REASON CODE : SWAP COMPONENT MPN: HG1050BD11 CPN: 3416133 TO POS: 2 SRL: 95050865 MPN: HG1050BD11 CPN: 3416133 TO POS: 2 SRL: 95050865 UPDT 26FEB21 05:53 MEM U SWAPPED #2 & #3 IRUS. REF A300-600 MM SEC 34-25-34-04. MEL 26FEB21 05:53 MEM U RELEASED FOR SERVICE PER MEL : 34-25-01 CATEGORY : C EXPIRATION : 08MAR21 "MEL 34-25-01: IRU NO. 3 - INOP."A/C CATII? RELEASED FOR SERVICE PER MEL : 34-25-01 CATEGORY : C EXPIRATION : 08MAR21 C/7260961 UPDT 26FEB21 05:53 MEM U FACT 26FEB21 22:03 MEM U R/R #3 IRU IAW AMM 34-25-34-04 ALSO REF WRI- 34-43/3203. MEL AND PLACARD REMOVED.