What was found
WHILE REPAIRING DAMAGE TO WEB IN BULK CARGO FLOOR BULKHEAD, FOUND CRACK MEASURING APPROX 5" IN RADIUS OF SUPPORT. REMOVED DAMAGED SECTION OF FLOOR SUPPORT. REQUIRES NDT FOR CRACK REMOVAL CHECK OF UPPER T SUPPORT AREA. PERFORMED HFEC OF UPPER TEE TRIMMED AREA, REF NDTSPM PT6. NO CRACKS NOTED. VERIFIED MATERIAL FOR FILLERS UNDER EXTRUSION REPAIR, PRIMED. INSTALLED ALL REPAIR PARTS REF SRM 53-00-00-2R AND EA 1-5310-T0359958, REV A, PART 2.