What was found
DURING HIGH FREQUENCY EDDY CURRENT SURFACE INSPECTION ON THE LEFT HAND NOSE LANDING GEAR TRUNNION FITTING AFT OF NOSE LANDING GEAR DOOR AFT HINGE FITTING SLOT OUT AREA AND FOUND 02 EACH CRACKS WITH LENGTH APPROXIMATELY 0.250" STATION 583 LEFT HAND NOSE LANDING GEAR TRUNNION FITTING STATION 583 REPAIR CARRIED OUT AS PER EA 1-5310-T0312182 A PART 3. TITLE: FUSELAGE - MAIN FRAME - LH NLG TRUNION FITTING CRACK INSPECTION. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.