What was found
04 EACH FASTENER HOLES # 9 , # 11 , # 12 , # 15 FOUND CRACK INDICATION DURING OPEN - HOLE HIGH FREQUENCY EDDY CURRENT INSPECTION AT RIGHT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 683.4 AND STATION XORS = 713.65. RIGHT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS 683.4 AND STATION XORS 713.65 04 EACH CRACK INDICATION FASTENER HOLES # 9 , # 11 , # 12 , # 15 , BUSHING REPAIR CARRIED OUT AS PER SRM 57-20-02-2R REPAIR 5 FIGURE 201. INITIAL INSPECTION TO BE CARRIED OUT AT 2000 FLIGHT CYCLES AND REPETITIVE INSPECTION TO BE CARRIED OUT AT EVERY 2000 FLIGHT CYCLES BY HIGH FREQUENCY EDDY CURRENT AND ULTRASONIC INSPECTION AS PER SRM 57-20-02-2R REPAIR 5 FIGURE 202 TABLE 201. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.