What was found
CABIN - LEFT HAND MAIN FRAME AT STATION 1761 LONGERON 12 LEFT EXISTING REPAIR ANGLE ANGLE FOUND DENT. CABIN - AT LEFT HAND MAINFRAME STATION 1761 LONGERON 12 LEFT , DENTED EXISTING REPAIR ANGLE REMOVED AS PER SRM 51-31-01-0G AND REPAIRED AS PER SRM 53-00-07-2R REPAIR 2 FIGURE 201. REPETITIVE INSPECTION REQUIRED - INITIAL AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT AS PER SRM 53-00-07-2R TABLE TABLE 201 REPAIR 2 - METHOD HIGH FREQUENCY EDDY CURRENT. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.