What was found
04 EACH FASTENER HOLES NUMBER #8 , 9 , 15 AND 34 FOUND CRACK INDICATION DURING OPEN - HOLE HFEC INSPECTION AT LEFT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 683-4 AND STATION = 713.6 . LEFT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 683.4 AND STATION XORS = 713.6, 04 EACH CRACK INDICTION FASTENER HOLES # 8 , 9 , 15 AND 34 BUSHING REPAIR CARRIED OUT AS PER MD-11 SRM 57-20-02-2R . FIGURE 201. REPAIR 5 . INITIAL INSPECTION TO BE CARRIED OUT AT 2000 FLIGHT CYCLES AND REPETITIVE INSPECTION TO BE CARRIED OUT AT EVERY 2000 FLIGHT CYCLES BY HFEC AND ULTRASONIC INSPECTION PER MD- 11. SRM 57-20-02-2R . FIGURE 202 / REPAIR 5 . TABLE 201 . REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.