What was found
09 EACH FASTENER HOLES NUMBER #7,8,9,11,13,14,27,33 AND 38 FOUND CRACK INDICATION DURING OPEN-HOLE HFEC INSPECTION AT RIGHT LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATIN XORS = 683.4 AND STATION = 713.6 . RIGHT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 683.4 AND STATION XORS = 713.6 09 EACH CRACK INDICTION FASTENER HOLES # 7 , 8 , 9 , 11 , 13 , 14 , 27 , 33 AND 38 BUSHING REPAIR CARRIED OUT AS PER MD - 11 , SRM 57-20-02-2R , FIGURE 201. REPAIR 5. INITIAL INSPECTION TO BE CARRIED OUT AT 2000 FLIGHT CYCLES AND REPETITIVE INSPECTION TO BE CARRIED OUT AT EVERY 2000 FLIGHT CYCLES BY HFEC AND ULTRASONIC INSPECTION PER MD-11 SRM 57-20-02-2R . FIGURE 202 / REPAIR 5 . TABLE 201 . REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.