What was found
NOSE LANDING CEAR LEFT HAND TRUNNION FITTING AT STATION 584 FOUND CRACK 1.25 INCHES IN LENGTH. NOSE LANDING GEAR LEFT HAND TRUNNION FITTING STATION 584 AREA REPAIRED AS PER SRM 53-10-14-2R REPAIR 2 FIGURE 202.INITIAL INSPECTION TO BE CARRIED OUT AT 1500 FLIGHT CYCLE AND REPETITIVE INSPECTION TO BE CARRY OUT EVERY 1500 FLIGHT CYCLE BY HIGH FREQUENCY EDDY CURRENT OR LIQUID PENETRANT INSPECTION AS SRM 53-10-14-2R TABLE 201/REPAIR 2 FIGURE 202/REPAIR 2. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.