As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
3EA WATER TRAPPED AREAS WERE FOUND ON THE T/E SCREW LINE (NO.6, NO.7 & NO.15) OF LH RUDDER SIDE PANEL IN AREA. THE MAX WATER TRAPPED AREA IS 85MM*60MM. REPAIRED THE 3EA WATER TRAPPED AREA (6.7.15) I.A.W A300-600F SRM 55-41-12-201 PARA.23 PAGE.305 TO PAGE.309 WITH FIG.222A. THIS IS CAT. B REPAIR I.A.W. A300-00F SRM 55-41-12-201 TABLE 202 AND SRI 55-41-12-2-006-00 PARA.3.F.