What was found
CRACK INDICATION ON FRAMEE 47 RH SIDE CORNER FITTING AT REAR SPAR AND BOTTOM PANEL JUNCTION WITH FUSELAGE AREA ON OPEN FASTENER HOLE C. AFFECTED LAYER IS REAR SPAR AND CRACK DIRECTIONS IS 12 OCLOCK IN CENTER FUEL TANK (1 EA) PERFORMED REPAIR INSTRUCTIONS ON FR47 FASTENER HOLE "C" RH SIDE IAW EA NO. 6-5710- T0308679 B P3 TITTLE WINGS - BASIC WING STRUCTURE - REAR SPAR AND BOTTOM PANEL AT JUNCTION WITH FUSELAGE / FRAME 47 FASTENER HOLES CRACK REPAIR * THIS EA DEVIATES FROM EO 6-5710-E0342809