What was found
PDIS 657 28-40 3702 18MAY21 BUR FACT U APPROX 8K ON DECENT RECEIVED TRIM TO AFT XFR NOT AVAIL, SECURED ALL INNER TANKS PER ECAM. SHORTLY THERE AFTER NOTICED FUEL ECAM DISPLAY ONLY INDICATED 1.3K IN RT OUTER, CTR 3.0K, LT OUTER 7.1K. OVERHEAD FUEL INDICATIONS SHOWED SAME. ON FINAL SYSTEM STABILIZED AT 7K IN OUTERS AND 3K CENTER WITH FOB TOTAL OF 18.4. AFTER DEBRIEF, CROSS VERIFIED RH OB FUEL QTY STICKS WITH ECAM AND OVERHEAD QTY INDICATIONS READ FULL REF 12-11-28-03. ON MTP NO FAULT INDICATIONS WERE ILLUMINATED. PERFORMED FQIC FAULT ISOLATION BITE, HAD 3 SOFT CODES ON INDICATCATOR. PERFORMED RESET OF FQIC AND ALL CODES CLEARED AND PROPER SAT TEST WAS OBSERVED. REF A300 TSM / MM 28-42-00-05-02 CGCC RECORDED NUISANSCE HI CAL LVL SENS FAULT AND 1 FQIS. SAT OPERATIONAL CK CGCC PERFORMED WITH NO FAULTS REF MM 31-46-00-05.