What was found
DURING ACCOMPLISHMENT OF HIGH FREQUENCY EDDY CURRENT INSPECTION AT LEFT HAND WING FIXED LEADING EDGE SKIN , FOUND CRACK INDICATION AT CORNER # 11 , APPROXIMATE 0.2 " IN LENGTH AT XOS 610.844. CRACK AT LEFT HAND WING FIXED LEADING EDGE SKIN AT CORNER # 11 AT XOS 610.844 REPAIRED AS PER SRM 57-10-00 FIGURE 107 SHEET 2 VOLUME I. INITIAL INSPECTION TO BE CARRIED OUT AT NEXT C CHECK NOT EXCEEDING 24 MONTHS AND REPETITIVE INSPECTIONS AT EVERY C CHECK NOT EXCEEDING 24 MONTHS AS PER SRM 57-10-00 FIGURE 107 PARAGRAPH 101.D. FOR MAINTENANCE REQUIREMENTS. METHOD : VISUAL. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.