What was found
1. 2 EA WATER TRAPPED AREAS (50MM X 50MM)(50MM X 50MM) WERE FOUND AT NO.22 & NO.28 FASTENER OF LH ELEVATOR UPPER SKIN PANEL. 2. 2 EA WATER TRAPPED AREAS WERE FOUND AT NO.2 & NO.7 FASTENER OF LH ELEVATOR LWR SKIN PANEL. THE MAX WATER TRAPPED AREA IS 50MM X 50MM. THE FFASTENER NO. COUNTING FROM I/B TO O/B. REPAIRED THE WATER TRAPPED AREAS (NO. 22, NO. 28, NO. 02, NO. 07) I.A.W. A300-600F SRM 55- 21-12-201, PARA. 5.F, FIG. 201, 209 AND 55-20-00-201 PARA. 5.D. THIS IS CAT. B REPAIR I.A.W. A300-600F SRM 55-21-12-201, P. 203, SRI 55-21-12-201, IIR 55-21-12- 2- 001-00 PARA.3.A.