What was found
MAIN DECK CARGO FORWARD COMPARTMENT FLOOR SEAT TRACK SPLICE FITTING FOUND WITH CORROSION X = - 8.5 STATION 625. MAIN DECK CARGO FORWARD COMPARTMENT FLOOR AT SEAT TRACK SPLICE FITTING STATION 625 , X = - 8.5 CORROSION EVALUATED FOUND EXFOLIATED AND EXCEEDED LIMIT AS PER MD-10 SRM 53-00-01 FIGURE 1A VOLUME 1. CORRODED SEAT TRACK SPLICE FITTING REMOVED AS PER MD-10 SRM 51-31-01 VOLUME 2. SPLICE FITTING FABRICATED AND INSTALLED AT SEAT TRACK STATION 625 , X = - 8.5 AS PER MD-10 SRM 53-70-00 FIGURE 1 VOLUME 1. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.