What was found
CABIN - LEFT HAND STATION 1561 LONGERON 12 LEFT FRAME FOUND DENT. CABIN - AT LEFT HAND FRAME STATION 1561 LONGERON 12 LEFT, DENT AREA REPAIRED AS PER MD-10 SRM 53-30-00 FIGURE 4 VOLUME 1. REPETITIVE INSPECTION REQUIRED - INITIAL AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT BY CLOSE VISUAL OR HIGH FREQUENCY EDDY CURRENT INSPECTION AS PER MD-10 SRM 53-30-00 FIGURE 4 VOLUME 1 AND SRM 53 - DTA TABLE 1 PARAGRAPH 3 VOLUME 1. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.