What was found
L/H FRAME 47 INSPECTION FOUND DAMAGEE AT AND SCORING IN THE HOLE OF FASTENER TO BE REVERSED.TOP FITTING AT .586" AND REMAINDER IS .563". HOLE SHOULD BE .5625 CLEAN AND ROUND. REPLACE FASTENER
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L/H FRAME 47 INSPECTION FOUND DAMAGEE AT AND SCORING IN THE HOLE OF FASTENER TO BE REVERSED.TOP FITTING AT .586" AND REMAINDER IS .563". HOLE SHOULD BE .5625 CLEAN AND ROUND. REPLACE FASTENER