What was found
DURING ACCOMPLISHMENT OF HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSPECTION ON ALL AFFECTED / ACCESSED FASTENER HOLES AT LEFT HAND NOSE LANDING GEAR TRUNNION IN ACCORDANCE WITH EA 1-5310-T0362355 P1 STEP 2, FOUND CRACK INDICATION ON FASTENER HOLE AT STATION 583 LONGERON 49 LEFT. LEFT HAND NOSE LANDING GEAR STATION 583 LONGERON 49 LEFT REMOVED AND REPLACED AS PER SRM 51-31-01-0G. FABRICATED LONGERON AS PER DOUGLAS DRAWING ACA3796 REVISION A. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.