What was found
CABIN - LEFT HAND STATION 1541 LONGERON 12 LEFT FRAME FOUND DENT. CABIN AT LEFT HAND FRAME STATION 1541 LONGERON 12 LEFT DENT AREA REPAIRED AS PER SRM 53-30-00 FIGURE 4 VOLUME 1. REPETITIVE INSPECTION REQUIRED - INITIAL AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT AS PER SRM 53 - DAMAGE TOLERANCE ASSESSMENT TABLE 1 VOLUME 1 , 53-30-00 PARAGRAPH 5 , FIGURE 4. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.