What was found
HIGH FREQUENCY EDDY CURRENT INSPECTION CARRIED OUT AROUND THE STOP DRILL ON LEFT HAND NOSE LANDING GEAR TRUNNION FITTING , STATION Y = 590 AND FOUND CRACK INDICATION PROPAGATED FROM THE STOP DRILL HOLE APPROXIMATE 1/4 INCHES LENGTH. CRACK AREA AT LEFT HAND NOSE LANDING GEAR TRUNNION FITTING , STATION Y = 590 REPAIRED AS PER ENGINEERING AUTHORIZATION # : 1-5340-154219 A P3 TITLE : FUSELAGE - LH NLG TRUNNION FITTING CRACK REPAIR , STA595 - SRM 53-10-14, REPAIR 2. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.