What was found
FUSELAGE MAINFRAME OVERWING FLOOR BEAM L/H SIDE AT STA 1256 LBL 112 IS CRACKED APPROX. ONE INCH IN LENGHT. (MKD) REPAIRED FUSELAGE MAINFRAME OVERWING FLOOR BEAM AT STA 1256 LBL112 REF BOEING SERVICE BULLETIN DC10-53-172 FIG 5, DWG SR10530081, EA 8-5310-T0363831 TITLED: FUSELAGE - MAINFRAME- CENTER FUSELAGE FLOOR SUPPORT INSTALLATION, STA 1256