What was found
MAIN DECK FLOORBOARD SUPPORT ANGLE STA. 1661 LBL=107.25 EXFOLIATED/CORRODED. (MRKD) REMOVED AND REPLACED WITH NEW FABRICATED FLOOR BOARD SUPPORT P/N AFA3853-501 REF DAC DWG AFA3853 AND SRM 51-33-01 VOL. 2