What was found
WORK ORDER 69707 SPECIAL/NONROUTINE MAINTENANCE FORM NUMBER N00328 MAJOR REPAIR, REQUIRED INSPECTION ITEM, JOB PROGRESS FORM ITEMS 4 TO 5 AND 7 TO 10 DO NOT HAVE REQUIRED INSPECTION ITEM BLOCK MARKED. EXISTING DOUBLER REMOVED AS PER SRM 51-33-01-0G AT LEFT HAND WING LEADING EDGE AT STATION XOS 789 AND FABRICATED DOUBLER PER DOUGLAS DRAWING ARB3954 REVISION K. INSTALLED FABRICATED DOUBLER AT LEFT HAND WING LEADING EDGE AT STATION XOS 789 AS PER SRM 51-33-01-0G. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.