What was found
PDIS 746 29-21 2911 22DEC21 MEM OPEN U DEPARTING KMEM27 AT APPROX 100 KNTS LOST GREEN SYSTEM HYDRAULIC PUMPS. NO APPARENT LOSS OF FLUID, JUST PSI. COMPLETE LOSS OF GREEN SYSTEM PRESSURE. ABLE TO RECOVER GREEN SYSTEM WITH PTU S. INFO 22DEC21 13:26 MC1 R ***********TECH UPDATE********* CAPT. WILLIAMS CALLED DESK AND NOTIFIED WAS ABLE TO REGAIN GREEN SYSTEM PRESSURE WITH THE GREEN ELECTRIC PUMPS. PTU'S WERE NOT USED DUE TO ONLY GREEN SYSTEM WAS AFFECTED. DID HAVE SERVO LTS OVERHEAD WITH LOW PRESSURE ON ECAM **********CARLOS/TECH SUPPORT*********** FACT 22DEC21 18:31 MEM SERVICED GREEN HYDRAULIC SYSTEM FLUID PER A300-600 AMM 29-00-00-03. PERFORMED INSPECTION AND CHECK OF THE GREEN HYDRAULIC SYSTEM PER A300-600 AMM 29-00-00-06 , OPERATED ALL FLIGHT CONTROL. NO DISCREPANCIES NOTED.