What was found
MAIN DECK LONGITUDIAL FLOOR STRUCTURE UPR SURFACE WAS FOUND CORROSION AT FR12A ~ FR13A , Y1450MM REPAIRED THE DAMAGE AREA WITH TEE SPLICE REPAIR I.A.W. A300-600F SRM 53-12-15-201-2 PARA.5.G P.239-244 FIG.207
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK LONGITUDIAL FLOOR STRUCTURE UPR SURFACE WAS FOUND CORROSION AT FR12A ~ FR13A , Y1450MM REPAIRED THE DAMAGE AREA WITH TEE SPLICE REPAIR I.A.W. A300-600F SRM 53-12-15-201-2 PARA.5.G P.239-244 FIG.207