What was found
JUST PRIOR TO LEVEL OFF, RECEIVED L CTR FUEL PUMP EICAS MESSAGE. COMPLIED WITH QRH. WITH MEL 28-22-02-A ALREADY ON AIRCRAFT FOR RIGHT CENTER PUMP, WE DID NOT HAVE SUFFICIENT FUEL TO CONTINUE TO DESTINATION. DIVERTED TO KMCI PER GOC REQUEST. UPON FURTHER INVESTIGATION FOLLOWING B757 FIM 28-22 FT 804, NOTED RH FUEL PUMP AT 3.3 OHMS BETWEEN PINS 1&2, 2&3 AND 1&3 WHILE LEFT PUMP 19 OHMS BETWEEN PINS 1&2, 2&3 AND 1&3. RH FUEL PUMP IS WEAK AND RECOMMEND REPLACEMENT. REMOVED AND REPLACED LH CENTER FUEL OVERRIDE PRESSURE SWITCH PER B757 AMM 28-42-01-4-1. OPS/LEAK CHECK OF PRESSURE SWITCH GOOD. RH FUEL OVERRIDE PUMP REQUIRES REPLACEMENT PRIOR TO CLEARING OF MEL. PARTS ON HAND IN IND. REMOVED AND REPLACED CTR TANK RIGHT HAND OVERPUMP I. A.W. 28-22-03-04 - OPS CHECKED GOOD .