What was found
MAIN CABIN LH SIDE FLOOR WEB LOWER STIFFENER HAS CORROSION ON LOWER SURFACE AT 1EA NUTPLATE LOCATION AT APPROX STA 1680 LBL 55 REMOVED CORROSION AS REQUIRED LH FLOOR WEB STIFFENER LOWER SURFACE, REMAINING MATERIAL IS .064", REMOVED .006", ORIGINAL .070" FOUND TO BE WITHIN LIMITS OF B757-200 SRM 53-60-15-0I GIG 1 DETAIL I AND B757-200 SRM 53-60-15-1A FIG 101 DETAIL VI AND ST MAE DWG 11864179