What was found
UNDOCUMENTED COMPOSITE REPAIR ON L/H WING OUTER AFT FLAP LOWER SURFACE 11" FROM AFT EDGE 105" FROM OUTBD EDGE PERFORMED WET LAYUP REPAIR FOR MENTIONED AREA PER SRM 51-70-17, REF SRM 57-53-01- 2R-1 REPAIR 1, FIG.201 DETAIL IV TABLE II REP.DIM: 4". REP. LOCATION 6.5" FROM T.E AND 152" FROM I/B EDGE. MAJOR REPAIR