What was found
PREVIOUS COMPOSITE MAJOR REPAIR LOCATED ON RIGHT SIDE OF RUDDER APPROX. 4 FT FROM THE BOTTOM AND 3 FT FROM TRAILING EDGE. REPAIR REQUIRES EVALUATION TO DETERMINE IF REPAIR IS IN ACCORDANCE WITH APPROVED DATA. ACCOMPLISHED THE CATE.B RUDDER SHELL CFRP AREA REPAIR I.A.W A300-600 SRM 55-41-12-201, PARA36, PAGE377-280, FIG229, SRI 55-41-12-201, IIR:55-41-12-2-011-00, PARA3L, PAGE243/244