What was found
FUSELAGE SKIN BETWEEN ACCESS DOOR 313AL CUT-OUT AND APU COMPARTMENT, INNER SURFACE IS CORRODED. REMOVED CORROSION FROM FUSELAGE SKIN BETWEEN ACCESS DOOR 313AL CUT-OUT AND APU COMPARTMENT INNER SURFACE IAW SRM 51-10-02-0G, 0.035" MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01-1A, FIG 101, DET.II. REMOVED AND REPLACED 148N3611-10 SKIN IAW SRM 51-40-02-0G AND DWG. 148N8402,148N3601, MAJOR REPAIR