What was found
DURING PERFORMING EA: T G-5710-T0366591 P1, STEP10.D.(4), AT STA1035 LBL70, QTY 01 HOLE REQUEST TO INSTALL BACB30WR5K()LX IN HOLE DIA.0.3232"-0.3252", AND NOW OVERSIZED TO 0.371". THE NEXT OVERSIZE FASTENER INSTALLED AT THE DISCREPANT FASTENER HOLE LOCATION AS PER EA G-5710-T0367508P1 ,TITLE :WING -BASIC WING STRUCTURE -CENTER WING RING CHORD FRONT SPAR LOWER CHORD AND WEB .LH AND RH UNDERWING LONGERON ,INSPECTION /MODIFICATION -DEVIATION TO SB777-57A0122RB .REFER TO WRI:57101088 FOR THE WORK DETAIL .REPAIR CLASSIFIED AS MAJOR PER GMM6-2-100.