What was found
EXISTING COMPOSITE REPAIR ON R/WING OTBD FLAP, LWR SURFACE T/E, APPROX 12" FROM INBD END AND 5" FROM T/E. EXISTING COMPOSITE REPAIR, R/WING OTBD FLAP, LWR SURFACE T/E, APPROX 12" FROM INBD END AND 5" FROM T/E., IS LOCATED ON A PRIMARY STRUCTURE PER B757-200 SRM 51-00-04-0G. COMPOSITE REPAIR RE-CLASSIFIED AS MAJOR