What was found
FORWARD CARGO BILGE FROM STATION 1119 - 6-10 LONGERON 52 SPLICE FITTING FOUND CORROSION. FORWARD CARGO BILGE FROM STATION 1119 TO STATION 6-10 AT LONGERON 52 SPLICE , CORROSION EVALUATED FOUND EXFOLIATED AND EXCEEDED LIMIT AS PER SRM 53-00-00-52- 2R FIGURE 205 REPAIR GENERAL. CORRODED LONGERON 52 SPLICE AT STATION 1119 TO STATION 6-10 REMOVED AND REPLACED AS PER SRM 51-31-01-0G. LONGERON 52 SPLICE FABRICATED BY MACHINING AS PER DOUGLAS DRAWING ADA8424 REVISION A. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.