Service difficulty report · Tube · Doug MD11F

Difficulty date
April 9, 2022
Submitted
April 11, 2022
Operation
Air carrier
Aircraft
N607FE
Make and model
Doug MD11F
Aircraft serial
48547
Aircraft time
89,759 hours, 21,856 cycles
Part
Tube
Condition
Failed
Location
Hyd Pump
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

2 49 INTO FLIGHT RECEIVED LEVEL ONE HYD 2 OFF ALERT FOLLOWED WITHIN 5 MIN. BY A LEVEL TWO HYD 2 FAIL ALERT. HYD SYSTEM 2 QUANTITY CONTINUED TO DECREASE UNTIL IT REACHED 0.3. EMERGENCY DECLARED. INSTALLED TUBE ASSY FOR NR 2 , HYDRAULIC SYS CASE DRAIN HYD PUMP LWR TO FILTER MANIFOLD ASSY IAW AMM 29-12-40-2. BLED HYD SYS IAW AMM 29-03-00-2. PERFORM DRY MOTOR FOR LEAK CHECKS, LEAK CHECKED GOOD. PERFORMED ENGINE RUNS, OPS CHECKED GOOD IAW AMM 29-11-20-4-1.