What was found
WHILE PERFORMING INTERNAL BORESCOPE INSPECTION (SPECIAL/NONROUTINE MAINTENANCE FORM NUMBER N00976), RIGHT HAND WING NUMBER 8 SLAT INTERNAL RIB FOUND CRACK AT LOOSE RIVETS AREA. RIGHT HAND WING NUMBER 8 SLAT INTERNAL LOOSE RIVETS AND CRACKED RIB AT STATION XOS 1092.116 REMOVED AND REPLACED AS PER SRM 57-40-01-2R REPAIR 13. RIB FABRICATED AS PER DOUGLAS DRAWING ARB1928 REVISION G. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2- 100.