What was found
RIGHT WING FIXED L/E AREA, FORMER HAS CRACK INDICATION AT THE I/B MAIN TRACK OF #9 SLAT APPROX. L/E STA. 562. REMOVED AND REPLACED THE OUTBD RIGHT WING FIXED L/E NOSE FORMER AND ATTACH ANGLE AT OSS 565 IAW BAC DWG 114T2162, REV. - AND FEDEX EA H-5720-T0367791-P1, TITLE: WING-SECONDARY WING STRCT - FIELD SERVICE EVALUATION, LH WING OSS 441 AND OSS 499, RH WING OSS 499 AND OSS 565, LEADING EDGE NOSE FORMER AND ATTACH ANGLE REPLACEMENT