What was found
EXISTING COMPOSITE REPAIR LOCATED ON L/WING INBD MAIN FLAP, UPPER SURFACE, 63" FROM OTBD EDGE AND 41" FROM T/E, REQUIRES EVALUATION TO DETERMINE IF REPAIR IS IN ACCORDANCE WITH APPROVED DATA EVALUATED EXISTING COMPOSITE REPAIR AND FOUND REPAIR TO CONFORM TO PREVIOUS OPERATORS WORK CARD,UNITED AIRLINES, SO#533016, NR#40832, IAW B757-200 SRM 57-53- 01-2R, FIG 201, REPAIR 1. RE CLASSIFIED REPAIR FROM MINOR TO MAJOR PER FEDEX GMM 06-2- 100