What was found
UNDOCUMENTED EXISTING REPAIR BETWEEN STA 1918.9-1941 LBL 16.5" DIMENSION 4.0"-4.3" PERFORMED DVI INSPECTION PER SRM 51-10-08 AND TAP TEST PER SRM 51-10-06, FOUND EXISTING REPAIR WITHIN GOOD CONDITION AND PERFORMED PER SRM 51-70-10-2R. REF. SRM 53-80-01-2R. REV. 135.0. MAJOR REPAIR