What was found
ON CLIMB OUT. LVL 1 HYD 3 ELEV OFF . HYD 3 QTY INDICATED 4.7 AND DROPPING. FOLLOWED BY A LVL 1 HYD 3 OFF AND THEN A LVL 2 HYD 3 FAIL . QTY AT ZERO. COMPLIED WITH QRH. EMERGENCY DECLARED DIVERT TO INDY AT GOC REQUEST. REMOVED AND REPLACED #1 HORIZONTAL STAB TRIM MOTOR IAW AMM 27-43-30-4. LEAK AND OPS CHECKED GOOD IAW AMM 27-43-30-4. ACFT OK FOR SERVICE.