What was found
DURING HIGH FREQUENCY EDDY CURRENT SURFACE REPETITIVE INSPECTION ON THE LEFT HAND NOSE LANDING GEAR TRUNION FITTING AFT OF NOSE LANDING GEAR DOOR AFT HINGE FITTING SLOT OUT AREA FOUND 01 EACH CRACKS WITH LENGTH APPROXIMATELY 0.2Ï¿½ AT STATION 575. AT HIGH FREQUENCY EDDY CURRENT SURFACE REPETITIVE INSPECTION ON LEFT HAND NOSE LANDING GEAR TRUNION FITTING AFT OF NOSE LANDING GEAR DOOR AFT HINGE FITTING SLOT OUT AREA WITH 01 EACH CRACK STATION 575 REPAIRED AS PER SRM 53-10- 14-2R REPAIR 2 FIGURE 202. REPETITIVE INSPECTION REQUIRED Ï¿½ INITIAL AT 1,500 CYCLES AND REPETITIVE INSPECTION AT 1,500 CYCLES TO BE CARRIED OUT AS PER SRM 53-10-14-2R REPAIR 2 TABLE 201 (FIGURE 202). REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.