What was found
LOWER AFT CARGO COMPARTMENT BETWEEN STATION 1897 AND STATION 1925 X - 57 CEILING FLOOR SUPPORT FOUND WITH CORROSION. LOWER AFT CARGO COMPARTMENT CEILING , AT FLOOR SUPPORT STATION 1897 AND STATION 1925 , X = - 57 CORROSION EVALUATED , FOUND EXFOLIATED AND EXCEEDED LIMIT AS PER SRM 53-00-00-2R FUGURE 206 REPAIR GENERAL. CORRODED FLOOR SUPPORT REMOVED AND REPLACED FROM STATION 1887 TO STATION 2007 , X = - 57 AS PER SRM 51-31-01-0G. FLOOR SPPORT FABRICATED BY MACHINING AS PER DOUGLAS DRAWING AGA 7551 REVISION G. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.