What was found
MDIS 631 25-60 2198 09AUG22 CDG OPEN U DURING RIGHT ENTRY SLIDE RAFT REPLACEMENT, FOUND RIGHT EVACUATION SLIDE REMOTE PRESSURE PRESS-TO-TEST BUTTON BROKEN MEL 09AUG22 09:24 CDG U RELEASED FOR SERVICE PER MEL : 25-61-02 CATEGORY : C EXPIRATION : 19AUG22 "MEL 25-61-02: __RIGHT_ EVAC SLIDE REMOTE PRESS INDICATOR - INOP. PER MEL 25-61-02, VERIFYAND RECORD IN THE AML, EVAC SLIDE SYS PRESS ADEQAUTE ONCE EACH FLIGHT DAY." C/7328324 FACT 11AUG22 18:59 OAK PROPERLY SECURED PUSH BUTTON LIGHT ASSY DUE LOOSE PER SMP AND ALSO REPLACED BATTERY DUE WEAK. CARRIED OUT SLIDE REAFT ADJ/TEST PER MD 11 MM25-61-06-5, SATISFACTORY. CLEARED MEL AND REMOVED STICKER.