What was found
DURING HIGH FREQUENCY EDDY CURRENT ON LEFT HAND OVERWING FLOOR BEAM AND THE UPPER AND LOWER FLANGES AT X = 90 TO X = 116 STATION Y = 1305, FOUND 02 EACH CRACK AT UPPER FLANGE 2ND FASTENER FROM INBOARD NEAR X = 116 AFT SIDE APPROXIMATELY CRACK 1.3Ï¿½ AND FORWARD SIDE APPROXIMATELY 2.0Ï¿½ LENGTH. LEFT HAND OVER WING FLOOR BEAM AT STATION Y = 1305 BETWEEN X = 90 TO X = 116 02 EACH CRACK AT UPPER FLANGE 2ND FASTENER FROM INBOARD NEAR X = 116 REPAIR CARRIED OUT AS PER EA: #1-5310-T0369942 PART 1 TITLE: FUSELAGE Ï¿½ MAINFRAME Ï¿½ MAIN DECK CARGO OVERWING FLOOR BEAM AT STA1305.250 CRACK REPAIR. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.