What was found
03 EACH FASTENER HOLES #12 , #35 , #36 FOUND CRACK INDICATION DURING HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSPECTION AT LEFT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 683.4 AND STATION XORS = 713.6 LEFT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 683.4 AND STATION XORS = 713.6, 03 EACH FASTENER HOLES #12, #35, #36 REPAIR CARRIED OUT AS PER SRM 57-20-02-2R REPAIR 5 FIGURE 201. TO PERFORM INITIAL INSPECTION AT 2,000 CYCLES AFTER COMPLETION OF THIS REPAIR AND REPETITIVE INSPECTION AT EVERY 2,000 CYCLES BY HIGH FREQUENCY EDDY CURRENT INSPECTION METHOD AS PER SRM 57-20-02-2R TABLE 201 REPAIR 5 FIGURE 202. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100. ORIG SUB DATE: 9/6/2022