As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN - MAIN DECK CARGO COMPARTMENT FLOOR PANEL #233FF BELOW BALLMAT AREA FOUND FORWARD EDGE BROKEN AT ( STATION 575 TO STATION 735 ) FLOOR PANEL #233FF WITH FORWARD BROKEN EDGE AT MAIN DECK STATION 575 - STATION 735 REMOVED AS PER AMM 53-21-04. FLOOR PANEL #233FF FABRICATED AS PER FEDEX DRAWING SRZ-25-005 REVISION R. FLOOR PANEL #233FF INSTALLED AS PER AMM 53-21-04. REPAIR CLASSIFIED MAJOR AS PER GMM 6-2-100.