Service difficulty report · O-Ring · Doug MD11F

Difficulty date
October 1, 2022
Submitted
October 11, 2022
Operation
Air carrier
Aircraft
N612FE
Make and model
Doug MD11F
Aircraft serial
48605
Aircraft time
88,822 hours, 21,933 cycles
Part
O-Ring
Part number
NAS1611217
Condition
Leaking
Location
Hyd System
Stage of operation
CR
How discovered
O
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CRUISE WE RECEIVED A LEVEL 1 HYD 1 OFF ALERT. COMPLIED WITH QRH. HYD 1 QUANTITY WAS 3.0 GALLONS. DECLARED AN EMERGENCY WITH MEMPHIS APPROACH IN ANTICIPATION OF A LEVEL 2 HYD 1 FAIL ALERT. COMPLIED WITH QRH AND PERFORMED AN APPROACH AND LANDING TO KMEM 36C. RECEIVED THE LEVEL 2 HYD 1 FAIL ALERT DURING LANDING ROLL. EXITED THE RUNWAY, SET THE PARKING BRAKE, STARTED THE APU, AND SHUTDOWN ALL 3 ENGINES. ***EMERGENCY DECLARED*** #1 EDP'S WERE NOT RAN DRY 1.6 GALLONS REMAINS IN SYSTEM 1, IN CENTER WHEEL WELL 1-3 RMP INLET LINE TO #1 S/O VALVE HAS A STATIC LEAK, POSSIBLE O RING RUPTURE. MORE T/S AND CLEANUP REQUIRED FOUND THE O RING FOR THE INLET FOR THE 1-3 RMP DAMAGED AND LEAKING. REMOVED AND RELACED INLET O-RING , ITEM 340 IN IPC 29-22-01-01, IAW AMM 29-22-20-2. OPS AND LEAK CHECKS ARE GOOD AT THIS TIME. ORIG SUB DATE: 10/3/2022

More about the Doug MD-11F