What was found
03 EACH FASTENER HOLES #6 , #10 , #28 FOUND CRACK INDICATION DURING HIGH FREQUENCY EDDY CURRENT OPEN-HOLE INSPECTION AT LEFT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 683.4 AND STATION XORS = 713.6. BUSHING REPAIR CARRIED OUT ON 03 EACH CRACKED FASTENER HOLES #6 , #10 , #28 AT LEFT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 683.4 AND STATION XORS = 713.6 AS PER SRM 57-20-02-2R REPAIR 5 FIGURE 201 SHEET 3. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.