What was found
02 EACH FASTENER HOLES #16 , #34 FOUND CRACK INDICATION DURING HIGH FREQUENCY EDDY CURRENT OPEN-HOLE INSPECTION AT RIGHT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 683.4 AND STATION XORS = 713.6. BUSHING REPAIR CARRIED OUT ON 02 EACH CRACKED FASTENER HOLES #16 , #34 AT RIGHT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS = 683.4 AND STATION XORS = 713.6 AS PER SRM 57-20-02-2R REPAIR 5 FIGURE 201 SHEET 3. INITIAL REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.