What was found
MAIN CABIN STA 640-660 LBL44, UNDER FLOOR PANEL, FLOOR SUPPORT CORRODED REMOVED, FABRICATED AND INSTALLED SUPPORT STRAP AND FILLER IAW VA DWG 3459 AND DWG 3458 REV L. ORIG SUBMISSION DATE: 12/20/2022
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN STA 640-660 LBL44, UNDER FLOOR PANEL, FLOOR SUPPORT CORRODED REMOVED, FABRICATED AND INSTALLED SUPPORT STRAP AND FILLER IAW VA DWG 3459 AND DWG 3458 REV L. ORIG SUBMISSION DATE: 12/20/2022