What was found
FOUND CORROSION ON INBD CREASE BEAM BETWEEN STA 860 TO 880 AT RBL 64 ACCOMPLISHED REPAIR IAW FEDEX EA F-5310-T0372513 P1 FUSELAGE- MAINFRAME: SEC 43, FLOOR STRUCTURE, CREASE BEAM INNER CHORD, STA 860-880, RBL 64, PERMANENT REPAIR. MAJOR REPAIR