What was found
MDCC UNDER FLOOR 1EA WEB CRACKED AT FR47, Y953-Y1456. REPAIRED MDCC UNDER FLOOR CRACKED WEB AT FR47, Y953-Y1456 PER A300-600F SRM53-15-15- 201 FIG.201.THIS IS CAT B REPAIR AND IT MUST BE INSPECTED AT DEFINED INTERVALS PER A300- 600F SRI53-15-15-2-002-00. INSPECTION THRESHOLD FROM REPAIR EMBODIMENT:24000FC, SUBSEQUENT INSPECTION AT INTERVAL OF 3000FC.INSPECTION METHOD: DETAILED VISUAL. MAJOR REPAIR IAW FEDEX GMM 6-2-100.